Faced vs unfaced batts — where the vapor retarder goes

Faced batts carry their own retarder to the warm side; unfaced batts need a separate poly sheet in Zones 5–8. Never compress a batt to fit.

Source: IRC R702.7 vapor retarders; ASTM C665
Use this diagram free on your site — grab the embed codeGet the code

What this diagram shows

Two top-down sections through a stud bay, exterior at top and interior (warm-in-winter) at bottom. Faced: the batt’s kraft facing acts as a Class II vapor retarder stapled to the stud faces on the interior side. Unfaced: the batt has no facing, so in cold climate zones a separate 6-mil polyethylene sheet is run across the interior side. An inset warns that an R-19 batt crammed into a 3.5-inch 2×4 cavity is compressed and only performs at about R-17.

Use this diagram — free

You're welcome to use this diagram on your own site, blog, handout, or lesson at no cost. The only condition is a visible credit link back to the source page. Copy the snippet below and paste it into your page — the credit is already included.

Please keep the credit link intact and don't alter the diagram itself. Redistribution as part of a competing diagram library or template pack isn't permitted. Questions? Reach us via the site.