High pressure, the PRV, and the expansion tank

Over 80 psi, a PRV is required to reduce it (IPC 604.8) — and because that closes the system, a thermal-expansion tank is required too (IPC 607.3).

Source: IPC 604.8 & 607.3
Use this diagram free on your site — grab the embed codeGet the code

What this diagram shows

Diagram of a home water service showing pressure control. The street can deliver over 100 psi; where static pressure exceeds 80 psi, a pressure-reducing valve (PRV) is required to bring it down to about 60 psi (IPC 604.8). Adding the PRV closes the system, so IPC 607.3 then requires a thermal-expansion tank on the water heater’s cold supply so heating cycles don’t spike the pressure.

Use this diagram — free

You're welcome to use this diagram on your own site, blog, handout, or lesson at no cost. The only condition is a visible credit link back to the source page. Copy the snippet below and paste it into your page — the credit is already included.